Note- Click the blue buttons on the image to be directed to the relevant product.

 

 

The Independent Ceiling Soundproofing System will help to reduce the transfer of louder airborne noise such as shouting, loud music and dogs barking.  It will also help to a small degree with the reduction in impact noise from footfall.  This soundproofing system incorporates the use of the MuteClip 2 part resilient bar system along with 15mm Acoustic Plasterboard and 5kg Soundproofing Mat.  The Independent Ceiling Soundproofing System can be used with timber joist or concrete ceiling.  We also recommend that any cavities are filled with mineral wool for increased performance.


 


Installation Guide

Please Note- This guide is written with the assumption that you have moderate knowledge and experience in construction or joinery.

  1. This system can either be mounted directly onto a concrete ceiling with timber battens or a timber joist ceiling.
  2. If the system is to be mounted onto timber joist remove the plaster and plasterboard to expose the timber stud.
  3. If using this system on a concrete ceiling first measure up the ceiling and mark out locations for the battens.
  4. Apply 5mm Resilient Sealing Tape to the side of the timber that will be in direct contact with the concrete.
  5. Ensuring the timber is at appropriate centres, securely anchor the timber to the ceiling.
  6. If there is currently none in place, fit mineral wool between the joists or timber battens, ensuring the mineral wool doesn’t sit beyond the edge of the timber frame. It should be friction held between the studs.
  7. On the timber joists or battens measure up, mark out and fit the correct locations for the MuteClips. The perimeter MuteClips must be no further than 100mm from the adjacent surfaces.  The channels are to be spaced out a maximum of 400mm apart.  The centres for the MuteClips are to vary between 400mm and 1200mm depending on the centres of the joists or battens. Create a diamond configuration.
  8. Attach the MuteClip Channels into the MuteClips.
  9. MuteClip Channels must overlap by 200m if necessary, fix 4 self-tapping screws into the shoulders of the Channels to maintain a secure join.
  10. The Channels must not overlap on a MuteClip. The Channels can be cut to length with metal shears or a hacksaw.
  11. Fix your first layer of 15mm Acoustic Plasterboard to the MuteClip Channels ensuring you leave a 5mm gap around the perimeter of the ceiling. Additionally ensure the screws aren’t so long that they touch the timber stud or brick wall.
  12. Seal the perimeter of the ceiling with AC95 Acoustic Sealant using a caulking gun.
  13. Attach 5kg Soundproofing Mat to the Acoustic Plasterboard using Advanced Acoustics Contact Adhesive ensuring you have a good bond between the mat and the plasterboard and that there is no trapped air. Smooth out with a stiff brush or roller. You may wish to cut the Soundproofing Mat in half to make handling easier.
  14. Tape the joints of the Soundproofing Mat with PVC Jointing Tape.
  15. Fix the second layer of 15mm Acoustic Plasterboard staggering the joints from the first layer. Maintain the 5mm gap from the adjacent surfaces.  Ensure that the screws are long enough to fix to the MuteClip Channel but not so long that they touch the brick or timber.
  16. Seal the 5mm gap with AC95 Acoustic Sealant.
  17. Scrim tape the plasterboard joints and finish with a plaster skim.
  18. MuteClip Channel must not be installed over any opening or vent in the ceiling. To overcome this, install a MuteClip and Channel section either side of the opening or vent to support the weight of the system.

System Thickness - Approx 80mm plus thickness of timber.

 

Fixings Required:

Battens to Concrete - Anchor Bolt

MuteClip to Battens or Joists -  5mm x 60mm Coarse Thread Wood

1st Plasterboard to Channel - 32mm Fine Thread Dry Wall Screw

2nd Plasterboard to Channel - 50mm Fine Thread Dry Wall Screw

MuteClip Channel Overlap - 20mm Steel Self-Tapping Screw